Material Safety Data Sheet
Piperylene, tech., 60%, cis and trans isomers
ACC# 30000
Section 1 - Chemical Product and Company Identification |
MSDS Name: Piperylene, tech., 60%, cis and trans isomers
Catalog Numbers:
AC207650000, AC207650010, AC207650500
Synonyms:
1,3-Pentadiene; 1-Methylbutadiene; Penta-1,3-diene; Pentadiene, 1,3-
Company Identification:
Acros Organics N.V.
One Reagent Lane
Fair Lawn, NJ 07410
For information in North America, call: 800-ACROS-01
For emergencies in the US, call CHEMTREC: 800-424-9300
Section 2 - Composition, Information on Ingredients
|
CAS# |
Chemical Name |
Percent |
EINECS/ELINCS |
504-60-9 |
Piperylene |
60 | 207-995-2 |
Section 3 - Hazards Identification
|
EMERGENCY OVERVIEW
Appearance: APHA: 25 max clear liquid. Flash Point: -28 deg C.
Danger! Extremely flammable liquid and vapor.
Vapor may cause flash fire. Causes eye, skin, and respiratory tract
irritation. May cause central nervous system depression.
Target Organs: Central nervous system,
respiratory system, eyes, skin.
Potential Health Effects
Eye:
Vapors cause eye irritation. Lachrymator (substance which
increases the flow of tears). Causes redness and pain. May cause
chemical conjunctivitis and corneal damage.
Skin:
Causes skin irritation. Causes redness and pain. May cause cyanosis
of the extremities.
Ingestion:
May cause gastrointestinal irritation with nausea, vomiting and
diarrhea. Possible aspiration hazard. May cause central nervous
system depression. Ingestion of large amounts may cause CNS
depression.
Inhalation:
Causes respiratory tract irritation. May cause effects similar to
those described for ingestion. May cause dyspnea (difficult or
labored breathing). Aspiration may lead to pulmonary edema. Vapors
may cause dizziness or suffocation. May cause burning sensation in
the chest.
Chronic:
Effects may be delayed.
Section 4 - First Aid Measures
|
Eyes:
Immediately flush eyes with plenty of water for at least 15 minutes,
occasionally lifting the upper and lower eyelids. Get medical aid. Do
NOT allow victim to rub eyes or keep eyes closed.
Skin:
Get medical aid. Flush skin with plenty of water for at least 15
minutes while removing contaminated clothing and shoes. Wash clothing
before reuse.
Ingestion:
Never give anything by mouth to an unconscious person. Get medical
aid. Do NOT induce vomiting. If conscious and alert, rinse mouth and
drink 2-4 cupfuls of milk or water.
Inhalation:
Get medical aid immediately. Remove from exposure and move to fresh
air immediately. If breathing is difficult, give oxygen. Do not use
mouth-to-mouth resuscitation if victim ingested or inhaled the
substance; induce artificial respiration with the aid of a pocket
mask equipped with a one-way valve or other proper respiratory
medical device.
Notes to Physician:
Treat symptomatically and supportively.
Section 5 - Fire Fighting Measures
|
General Information:
As in any fire, wear a self-contained breathing apparatus in
pressure-demand, MSHA/NIOSH (approved or equivalent), and full
protective gear. Vapors can travel to a source of ignition and flash
back. During a fire, irritating and highly toxic gases may be
generated by thermal decomposition or combustion. Use water spray to
keep fire-exposed containers cool. Containers may explode in the
heat of a fire. May form explosive peroxides. Vapors may be heavier
than air. They can spread along the ground and collect in low or
confined areas. Extremely flammable liquid and vapor. Vapor may cause
flash fire.
Extinguishing Media:
Use water spray to cool fire-exposed containers. Use foam, dry
chemical, or carbon dioxide. This material is lighter than water and
insoluble in water. The fire could easily be spread by the use of
water in an area where the water cannot be contained. Do NOT use
straight streams of water.
Flash Point: -28 deg C ( -18.40 deg F)
Autoignition Temperature: Not applicable.
Explosion Limits, Lower:1.00 vol %
Upper: 7.00 vol %
NFPA Rating:
(estimated) Health: 2; Flammability: 3; Instability: 2
Section 6 - Accidental Release Measures
|
General Information: Use proper personal protective equipment as indicated
in Section 8.
Spills/Leaks:
Absorb spill with inert material (e.g. vermiculite, sand or earth),
then place in suitable container. Avoid runoff into storm sewers and
ditches which lead to waterways. Remove all sources of ignition. Use
a spark-proof tool. Provide ventilation. A vapor suppressing foam
may be used to reduce vapors.
Section 7 - Handling and Storage
|
Handling:
Ground and bond containers when transferring material. Use
spark-proof tools and explosion proof equipment. Avoid contact with
eyes, skin, and clothing. Empty containers retain product residue,
(liquid and/or vapor), and can be dangerous. Keep away from heat,
sparks and flame. Avoid ingestion and inhalation. Use only in a
chemical fume hood. Do not pressurize, cut, weld, braze, solder,
drill, grind, or expose empty containers to heat, sparks or open
flames.
Storage:
Keep away from heat, sparks, and flame. Store in a tightly closed
container. Store in a cool, dry, well-ventilated area away from
incompatible substances. Refrigerator/flammables.
Section 8 - Exposure Controls, Personal Protection
|
Engineering Controls:
Facilities storing or utilizing this material should be equipped
with an eyewash facility and a safety shower. Use adequate general or
local explosion-proof ventilation to keep airborne levels to
acceptable levels.
Exposure Limits
Chemical Name |
ACGIH |
NIOSH |
OSHA - Final PELs |
Piperylene
|
none listed
|
none listed
|
none listed
|
OSHA Vacated PELs:
Piperylene:
No OSHA Vacated PELs are listed for this chemical.
Personal Protective Equipment
Eyes:
Wear appropriate protective eyeglasses or chemical
safety goggles as described by OSHA's eye and face
protection regulations in 29 CFR 1910.133 or European
Standard EN166.
Skin:
Wear appropriate protective gloves to prevent skin
exposure.
Clothing:
Wear appropriate protective clothing to prevent skin
exposure.
Respirators:
A respiratory protection program that meets OSHA's 29
CFR 1910.134 and ANSI Z88.2 requirements or European
Standard EN 149 must be followed whenever workplace
conditions warrant respirator use.
Section 9 - Physical and Chemical Properties
|
Physical State: Clear liquid
Appearance: APHA: 25 max
Odor: None reported.
pH: Not available.
Vapor Pressure: 450 mbar @ 20 deg C
Vapor Density: 2.3
Evaporation Rate:Not available.
Viscosity: Not available.
Boiling Point: 42 deg C @ 760.00mm
Freezing/Melting Point:-78 deg C
Decomposition Temperature:Not available.
Solubility: insoluble
Specific Gravity/Density:.6830g/cm3
Molecular Formula:CH3CH=CHCH=CH2
Molecular Weight:68.11
Section 10 - Stability and Reactivity
|
Chemical Stability:
Stable at room temperature in closed containers under normal storage
and handling conditions.
Conditions to Avoid:
High temperatures, incompatible materials, ignition sources, excess
heat.
Incompatibilities with Other Materials:
Strong oxidizing agents.
Hazardous Decomposition Products:
Carbon monoxide, carbon monoxide, carbon dioxide.
Hazardous Polymerization: May occur.
Section 11 - Toxicological Information
|
RTECS#:
CAS# 504-60-9:
RZ2464000
LD50/LC50:
CAS# 504-60-9:
Inhalation, mouse:
LC50 = 1100 mg/m3/2H;
Inhalation,
mouse: LC50 = 9760 mg/m3/2H;
Inhalation, rat: LC50 = 140
gm/m3/2H;
Inhalation, rat: LC50 =
97200 mg/m3/4H;
.
Carcinogenicity:
CAS# 504-60-9:
Not listed by ACGIH, IARC, NTP, or CA Prop 65.
Epidemiology:
No information found
Teratogenicity:
No information found
Reproductive Effects:
No information found
Mutagenicity:
No information found
Neurotoxicity:
No information found
Other Studies:
Section 12 - Ecological Information
|
Ecotoxicity:
No data available.
No information available.
Environmental:
Will volatilize rapidly from both soil and water. Has high mobility
in soil, and will not leach to groundwater systems. Will not
hydrolyze, adsorb so suspended solids, or bioconcentrate in aquatic
organisms. Undergoes rapid gas phase reactions with hydroxyl
radicals and ozone. Reaction with nitrites at night in cities may be
an important fate process. Wet deposition may be used to remove, but
substance will most likely re-volatilze quickly, so this method may
be ineffective.
Physical:
No information available.
Other:
No information available.
Section 13 - Disposal Considerations
|
Chemical waste generators must determine whether a discarded chemical is classified
as a hazardous waste.
US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3.
Additionally, waste generators must consult state and local hazardous waste regulations to
ensure complete and accurate classification.
RCRA P-Series: None listed.
RCRA U-Series:
CAS# 504-60-9: waste
number U186 (Ignitable waste).
Section 14 - Transport Information
|
|
US DOT |
Canada TDG |
Shipping Name: |
FLAMMABLE LIQUIDS, N.O.S. |
FLAMMABLE LIQUID NOS (PIPERYLENE) |
Hazard Class: |
3 |
3 |
UN Number: |
UN1993 |
UN1993 |
Packing Group: |
II |
II |
Additional Info: | | FP -28C |
Section 15 - Regulatory Information
|
US FEDERAL
TSCA
CAS# 504-60-9 is listed on the TSCA inventory.
Health & Safety Reporting List
None of the chemicals are on the Health & Safety Reporting List.
Chemical Test Rules
None of the chemicals in this product are under a Chemical Test Rule.
Section 12b
None of the chemicals are listed under TSCA Section 12b.
TSCA Significant New Use Rule
None of the chemicals in this material have a SNUR under TSCA.
CERCLA Hazardous Substances and corresponding RQs
CAS# 504-60-9: 100 lb final RQ; 45.4 kg final RQ
SARA Section 302 Extremely Hazardous Substances
None of the chemicals in this product have a TPQ.
Section 313
No chemicals are reportable under Section 313.
Clean Air Act:
This material does not contain any hazardous air pollutants.
This material does not contain any Class 1 Ozone depletors.
This material does not contain any Class 2 Ozone depletors.
Clean Water Act:
None of the chemicals in this product
are listed as Hazardous Substances under the CWA.
None of the chemicals in this
product are listed as Priority Pollutants under the CWA.
None of the chemicals in this
product are listed as Toxic Pollutants under the CWA.
OSHA:
None of the chemicals in this product
are considered highly hazardous by OSHA.
STATE
CAS# 504-60-9 can be found on the
following state right to know lists: New Jersey, Pennsylvania,
Massachusetts.
California Prop 65
California No Significant Risk Level:
None of the chemicals in this product are listed.
European/International Regulations
European Labeling in Accordance with EC Directives
Hazard Symbols:
XI F
Risk Phrases:
R 11 Highly flammable.
R 36/37/38 Irritating to eyes, respiratory system and skin.
Safety Phrases:
S 16 Keep away from sources of ignition - No smoking.
S 26 In case of contact with eyes, rinse immediately with plenty of
water and seek medical advice.
S 37/39 Wear suitable gloves and eye/face protection.
WGK (Water Danger/Protection)
CAS# 504-60-9: No information available.
Canada - DSL/NDSL
CAS# 504-60-9 is listed on Canada's DSL List.
Canada - WHMIS
This product has a WHMIS classification of B2.
This product has been classified in accordance with the hazard
criteria of the Controlled Products Regulations and the MSDS
contains all of the information required by those regulations.
Canadian Ingredient Disclosure List
Section 16 - Additional Information
|
MSDS Creation Date: 9/02/1997
Revision #9 Date: 11/20/2008
The information above is believed to be accurate and represents the best
information currently available to us. However, we make no warranty of
merchantability or any other warranty, express or implied, with respect to
such information, and we assume no liability resulting from its use. Users
should make their own investigations to determine the suitability of the
information for their particular purposes. In no event shall Fisher be liable
for any claims, losses, or damages of any third party or for lost profits
or any special, indirect, incidental, consequential or exemplary
damages, howsoever arising, even if Fisher has been advised of
the possibility of such damages.