Material Safety Data Sheet
2,4-Dimethyl-3-pentanol
ACC# 32180
Section 1 - Chemical Product and Company Identification |
MSDS Name: 2,4-Dimethyl-3-pentanol
Catalog Numbers:
AC169530000, AC169530500
Synonyms:
Diisopropylcarbinol.
Company Identification:
Acros Organics N.V.
One Reagent Lane
Fair Lawn, NJ 07410
For information in North America, call: 800-ACROS-01
For emergencies in the US, call CHEMTREC: 800-424-9300
Section 2 - Composition, Information on Ingredients
|
CAS# |
Chemical Name |
Percent |
EINECS/ELINCS |
600-36-2 |
2,4-Dimethyl-3-pentanol |
>94 | 209-993-7 |
Section 3 - Hazards Identification
|
EMERGENCY OVERVIEW
Appearance: clear, colorless. Flash Point: 37 deg C.
Warning! Flammable liquid and
vapor. May cause irritation. The toxicological
properties of this material have not been fully investigated.
Target Organs: None.
Potential Health Effects
Eye:
May cause eye irritation.
Skin:
May cause skin irritation.
Ingestion:
May cause irritation of the digestive tract. The toxicological
properties of this substance have not been fully investigated.
Inhalation:
May cause respiratory tract irritation. The toxicological properties
of this substance have not been fully investigated. Vapors may cause
dizziness or suffocation.
Chronic:
No information found.
Section 4 - First Aid Measures
|
Eyes:
Flush eyes with plenty of water for at least 15 minutes, occasionally
lifting the upper and lower eyelids. Get medical aid immediately.
Skin:
Get medical aid. Flush skin with plenty of water for at least 15
minutes while removing contaminated clothing and shoes. Remove
contaminated clothing and shoes.
Ingestion:
If victim is conscious and alert, give 2-4 cupfuls of milk or water.
Never give anything by mouth to an unconscious person. Get medical
aid immediately. Do NOT induce vomiting. If conscious and alert,
rinse mouth and drink 2-4 cupfuls of milk or water.
Inhalation:
Remove from exposure and move to fresh air immediately. If not
breathing, give artificial respiration. If breathing is difficult,
give oxygen. Get medical aid.
Notes to Physician:
Treat symptomatically and supportively.
Section 5 - Fire Fighting Measures
|
General Information:
Get medical aid. As in any fire, wear a self-contained breathing
apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent),
and full protective gear. Vapors may form an explosive mixture with
air. Vapors can travel to a source of ignition and flash back. Use
water spray to keep fire-exposed containers cool. Flammable liquid
and vapor. Vapors may be heavier than air. They can spread along
the ground and collect in low or confined areas.
Extinguishing Media:
For small fires, use dry chemical, carbon dioxide, water spray or
alcohol-resistant foam. Use water spray to cool fire-exposed
containers. Do NOT use straight streams of water. For large fires,
use dry chemical, carbon dioxide, alcohol-resistant foam, or water
spray. Cool containers with flooding quantities of water until well
after fire is out.
Flash Point: 37 deg C ( 98.60 deg F)
Autoignition Temperature: 48.9 deg C ( 120.02 deg F)
Explosion Limits, Lower:N/A
Upper: N/A
NFPA Rating:
(estimated) Health: ; Flammability: 3; Instability: 0
Section 6 - Accidental Release Measures
|
General Information: Use proper personal protective equipment as indicated
in Section 8.
Spills/Leaks:
Absorb spill with inert material (e.g. vermiculite, sand or earth),
then place in suitable container. Clean up spills immediately,
observing precautions in the Protective Equipment section. Remove all
sources of ignition. Provide ventilation. A vapor suppressing foam
may be used to reduce vapors.
Section 7 - Handling and Storage
|
Handling:
Wash thoroughly after handling. Remove contaminated clothing and
wash before reuse. Use with adequate ventilation. Ground and bond
containers when transferring material. Avoid contact with eyes, skin,
and clothing. Empty containers retain product residue, (liquid and/or
vapor), and can be dangerous. Keep container tightly closed. Keep
away from heat, sparks and flame. Avoid ingestion and inhalation. Do
not pressurize, cut, weld, braze, solder, drill, grind, or expose
empty containers to heat, sparks or open flames.
Storage:
Keep away from heat, sparks, and flame. Keep away from sources of
ignition. Store in a tightly closed container. Store in a cool, dry,
well-ventilated area away from incompatible substances.
Flammables-area.
Section 8 - Exposure Controls, Personal Protection
|
Engineering Controls:
Use adequate ventilation to keep airborne concentrations low.
Ventilation fans and other electrical service must be non-sparking
and have an explosion-proof design.
Exposure Limits
Chemical Name |
ACGIH |
NIOSH |
OSHA - Final PELs |
2,4-Dimethyl-3-pentanol
|
none listed
|
none listed
|
none listed
|
OSHA Vacated PELs:
2,4-Dimethyl-3-pentanol:
No OSHA Vacated PELs are listed for this chemical.
Personal Protective Equipment
Eyes:
Wear appropriate protective eyeglasses or chemical
safety goggles as described by OSHA's eye and face
protection regulations in 29 CFR 1910.133 or European
Standard EN166.
Skin:
Wear appropriate protective gloves to prevent skin
exposure.
Clothing:
Wear appropriate protective clothing to prevent skin
exposure.
Respirators:
Follow the OSHA respirator regulations found in 29
CFR 1910.134 or European Standard EN 149. Use a
NIOSH/MSHA or European Standard EN 149 approved
respirator if exposure limits are exceeded or if
irritation or other symptoms are experienced.
Section 9 - Physical and Chemical Properties
|
Physical State: Liquid
Appearance: clear, colorless
Odor: None reported.
pH: Not available.
Vapor Pressure: Not available.
Vapor Density: 4.0
Evaporation Rate:Not available.
Viscosity: Not available.
Boiling Point: 139-140 deg C
Freezing/Melting Point:-70 deg C
Decomposition Temperature:Not available.
Solubility: 32.4 g/l @ 20°C
Specific Gravity/Density:0.820 g/ml
Molecular Formula:C7H16O
Molecular Weight:116.20
Section 10 - Stability and Reactivity
|
Chemical Stability:
Stable under normal temperatures and pressures.
Conditions to Avoid:
Ignition sources.
Incompatibilities with Other Materials:
Strong oxidizing agents.
Hazardous Decomposition Products:
Carbon monoxide, carbon dioxide.
Hazardous Polymerization: Has not been reported.
Section 11 - Toxicological Information
|
RTECS#:
CAS# 600-36-2:
SA6660000
LD50/LC50:
Not available.
Carcinogenicity:
CAS# 600-36-2:
Not listed by ACGIH, IARC, NTP, or CA Prop 65.
Epidemiology:
No information available.
Teratogenicity:
No information available.
Reproductive Effects:
No information available.
Mutagenicity:
No information available.
Neurotoxicity:
No information available.
Other Studies:
Section 12 - Ecological Information
|
No information available.
Section 13 - Disposal Considerations
|
Chemical waste generators must determine whether a discarded chemical is classified
as a hazardous waste.
US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3.
Additionally, waste generators must consult state and local hazardous waste regulations to
ensure complete and accurate classification.
RCRA P-Series: None listed.
RCRA U-Series: None listed.
Section 14 - Transport Information
|
|
US DOT |
Canada TDG |
Shipping Name: |
ALCOHOLS, N.O.S. |
Alcohols, N.O.S. |
Hazard Class: |
3 |
3 |
UN Number: |
UN1987 |
UN1987 |
Packing Group: |
III |
III |
Section 15 - Regulatory Information
|
US FEDERAL
TSCA
CAS# 600-36-2 is listed on the TSCA inventory.
Health & Safety Reporting List
None of the chemicals are on the Health & Safety Reporting List.
Chemical Test Rules
None of the chemicals in this product are under a Chemical Test Rule.
Section 12b
None of the chemicals are listed under TSCA Section 12b.
TSCA Significant New Use Rule
None of the chemicals in this material have a SNUR under TSCA.
CERCLA Hazardous Substances and corresponding RQs
None of the chemicals in this material have an RQ.
SARA Section 302 Extremely Hazardous Substances
None of the chemicals in this product have a TPQ.
Section 313
No chemicals are reportable under Section 313.
Clean Air Act:
This material does not contain any hazardous air pollutants.
This material does not contain any Class 1 Ozone depletors.
This material does not contain any Class 2 Ozone depletors.
Clean Water Act:
None of the chemicals in this product
are listed as Hazardous Substances under the CWA.
None of the chemicals in this
product are listed as Priority Pollutants under the CWA.
None of the chemicals in this
product are listed as Toxic Pollutants under the CWA.
OSHA:
None of the chemicals in this product
are considered highly hazardous by OSHA.
STATE
CAS# 600-36-2 is not present on
state lists from CA, PA, MN, MA, FL, or NJ.
California Prop 65
California No Significant Risk Level:
None of the chemicals in this product are listed.
European/International Regulations
European Labeling in Accordance with EC Directives
Hazard Symbols:
Not available.
Risk Phrases:
R 10 Flammable.
Safety Phrases:
S 16 Keep away from sources of ignition - No smoking.
WGK (Water Danger/Protection)
CAS# 600-36-2: 1
Canada - DSL/NDSL
CAS# 600-36-2 is listed on Canada's NDSL List.
Canada - WHMIS
This product has a WHMIS classification of B2.
This product has been classified in accordance with the hazard
criteria of the Controlled Products Regulations and the MSDS
contains all of the information required by those regulations.
Canadian Ingredient Disclosure List
Section 16 - Additional Information
|
MSDS Creation Date: 11/06/1998
Revision #5 Date: 11/05/2007
The information above is believed to be accurate and represents the best
information currently available to us. However, we make no warranty of
merchantability or any other warranty, express or implied, with respect to
such information, and we assume no liability resulting from its use. Users
should make their own investigations to determine the suitability of the
information for their particular purposes. In no event shall Fisher be liable
for any claims, losses, or damages of any third party or for lost profits
or any special, indirect, incidental, consequential or exemplary
damages, howsoever arising, even if Fisher has been advised of
the possibility of such damages.